Sentinel Dual SDU

Technical sheet : Sentinel Dual SDU


Simplified installation
-
Possibility of installation on the ground (tower version) or in a cabinet (rack version). It is possible to turn the display panel (using the key supplied);
-
Low noise level (<48 dBA): for installation in any environment, thanks to its inverter with high switching frequency and PWM fan with digital control depending on the applied load;
-
Connection possible via external maintenance bypass with continuous switching;
-
Guaranteed characteristics up to 40 ° C (components are designed for high temperatures and therefore undergo less stress in the presence of ordinary temperatures);
-
Integrated IEC-type output sockets with thermal protection.
Selecting the operating mode
The functions are programmable from software or manually configurable using the front display.
-
ON LINE: efficiency up to 95%;
-
ECO mode: to increase efficiency (up to 98%), it allows selection of LINE INTERACTIVE (VI) technology to supply insensitive loads from the network;
-
SMART ACTIVE: the UPS decides, independently, of the operating mode (VI or VFI) according to the quality of the mains power supply.
-
STANDBY OFF: the UPS can be selected to operate only in the event of a network failure (emergency mode only);
-
Frequency converter operation (50 or 60 Hz).
High quality of the output voltage
-
Even with non-linear loads (IT loads with crest factor up to 3: 1);
-
High short-circuit current on bypass; High overload capacity: 150% per inverter (even in the event of a grid failure);
-
Filtered, stabilized and reliable voltage: ON LINE double conversion technology (PFD in accordance with EN62040-3) with filters for the suppression of atmospheric disturbances;
-
Power factor correction: UPS input power factor close to 1 and sinusoidal current absorption.
-
Batteries can be replaced by the user, without the need to stop the device and without interrupting the charge (Hot Swap);
-
Unlimited extendable autonomy using battery cabinets;
-
The batteries do not intervene in the event of a mains failure <20 ms (high waiting time) or if the input power supply is between 184 V and 276 V.
Other characteristics
-
Selectable output voltage (220/230/240 V);
-
Power supply configuration of two input devices (SDU 10000 DI and SDU 10000 DI ER);
-
Auto-restart on restoration of the mains (programmable by software);
-
Bypass On: when the machine is off, it is automatically prepared for operation by the bypass and with the batteries charged;
-
Shutdown for minimum load;
-
Notice of total battery discharge;
-
Start-up delay; T
-
otal control by microprocessors and DSP;
-
Automatic bypass without interruption;
-
Use of customized power modules;
-
States, measurements, alarms available on standard backlit screen;
-
UPS digital update (flash memory upgradeable);
-
Protection of output sockets by resettable thermal switch;
-
Standard power return protection: to prevent energy returns to the network;
-
Manual switching to bypass.